Skip to content

Pharma · customer story

Velden Pharma answers its GDP auditor while she is still on the call.

A pharma wholesaler running 2–8 °C and room-temperature lanes moved from USB loggers to calibrated probes with mean kinetic temperature on every shipment.

0 min

To answer an auditor's request for one shipment, from three days

PDF from the trip page

0%

Of excursion investigations closed within 24 hours, from 18%

MKT and audit trail on the record

0 USB loggers

Left to collect, download and file at the depot

Was 1,900 a month

Velden Pharma distributes prescription medicines, vaccines and insulin to hospital pharmacies and 900 retail pharmacies. Most of its lanes run at 2–8 °C, the rest at controlled room temperature, and every one of them is inspected against Good Distribution Practice.

Until 2023, temperature evidence lived on USB data loggers: one in each van, collected at the end of the shift, downloaded at the depot and filed by date. Head of Quality Tomasz Wierzbicki's team handled about 1,900 loggers a month. When a pharmacy reported a warm delivery, the investigation started when the logger came back, which could be three days later.

An audit request that took three days

The breaking point was an inspection. An auditor asked for the temperature history of a handful of shipments from the previous spring. It took the team three days to find the files, match them to the right vans and print them, and one logger had been overwritten.

Excursion investigations closed within 24 hours12 months · %

Before Waypoint, an investigation waited for the van's USB logger to come back to the depot. After, it starts from the alert, with the curve and MKT already computed.

Excursion investigations closed within 24 hours
Month 116 %
Month 221 %
Month 314 %
Month 418 %
Month 522 %
Month 617 %
Month 758 % (Waypoint live)
Month 879 %
Month 988 %
Month 1091 %
Month 1196 %
Month 1294 %

Validating the system first

Velden's QA team would not use a system they had not validated, so the project started on paper. Waypoint's Enterprise GDP pack gave them templates for the user requirements, installation and operational qualification, which Velden adapted and executed on two vans and one reefer over four weeks. The summer performance qualification ran alongside the roll-out.

  1. URS and supplier assessment, using Waypoint's development and change control summary.
  2. IQ and OQ on three vehicles: probe placement, alarm delays, buffering through dead zones.
  3. Temperature mapping of each reefer type with twelve probes, to choose where the permanent probe goes.
  4. PQ over a summer and a winter month, on the real lanes.

Mean kinetic temperature on every trip

The change pharmacists noticed first was the record. Every delivery now closes with a page showing the curve since loading, the time out of range and the mean kinetic temperature, computed with the activation energy their stability data assumes. A short warm spike that used to trigger a quarantine now arrives with the number that shows it did not matter, and the investigation is closed the same day.

The auditor did not ask how we found the file. She asked whether every shipment has one. They do.
Tomasz Wierzbicki, Head of Quality, Velden Pharma

Signed, with a reason

Every alarm acknowledged, rule changed or shipment released in Waypoint asks for a password and a reason, and lands in an audit trail kept for seven years. Wierzbicki's team exports it for self-inspections; at the last GDP inspection there were no findings on transport.

Before and after
USB loggersWaypoint
Evidence for one shipmentUp to 3 days10 minutes
Investigation startsWhen the logger is backAt the alert
MKTCalculated by hand, on requestOn every record
Loggers handled per month1,9000
25400 MM1234LOGGER · 2–8 °CSHIPPER · A–AINSULATIONVIP 25 mmPACKSPCM +5 °CHOLD TIME96 h
“Our GDP auditor asked for the temperature history of one shipment from March. I sent her the PDF from the trip page while she was still on the call.”
TWTomasz WierzbickiHead of Quality, Velden Pharma
Waypoint for pharma

Measure your own before and after.

The 30-day pilot runs on real hardware. We track the numbers Velden Pharma tracked, on five of your vehicles, and send you the report.

References available on request

052° · 8.1 MI097° · 6.4 MI037° · 9.0 MIETA 15:48NORTHGATE DCWP1WP2WP3BN5 MI