Skip to content

Pre-cool the box, not the load

A reefer unit is built to hold a temperature, not to pull one down. Most warm pallets we investigate were loaded warm, or loaded into a warm box. Here is the loading routine that fixes it.

Ines DuarteCold-chain lead

On this page
  1. 1A reefer holds temperature, it does not make it
  2. 2Pre-cool the empty box, with the doors shut
  3. 3Check the product, not just the air
  4. 4Leave room for the air
  5. 5The routine, in order
  6. 6What the tracker can and cannot tell you

Last spring a customer sent us a rejection slip: one pallet of chicken thighs at 7.2 °C on a 0–4 °C order, refused at the dock at 06:40. The trailer record looked clean. The unit ran all night, the rear probe never left 3–4 °C after the first hour, and the doors stayed shut from the shipper to the receiver. The product was simply loaded at 7 °C, and eleven hours of cold air moving around the outside of a stretch-wrapped pallet did not change its core.

We see some version of this every week. When a load arrives warm, the first suspect is the reefer, and the reefer is usually innocent. The causes are upstream: a box that was warm when the first pallet went in, product that was warm when it left the shipper, or air that could not get where it needed to go.

A reefer holds temperature, it does not make it

A trailer refrigeration unit is sized to remove the heat that leaks in through the walls, the floor and the door seals, plus whatever the product gives off. It cools air, and that air has to travel over the surface of the load to take heat away. Pulling a dense pallet down by several degrees that way takes many hours, and while the unit works on it, everything near that pallet sits warmer than it should.

So the rule is plain: product goes into a trailer at the temperature it should travel at. The trailer's job is to keep it there.

Pre-cool the empty box, with the doors shut

An empty trailer parked in the sun can sit at 30 °C inside. Load chilled product into that and the walls, floor and air give their heat to the first pallets in. Run the unit with the doors closed until the return air reads the set point, then back onto the dock.

0–4 °C ORDER RANGE0°10°20°30°13:3014:0014:3015:0015:3016:0016:30PRE-COOL · DOORS SHUTLOADING · UNIT OFFSEALED · RECOVERY8.4° doors close
Rear probe of a 53 ft reefer on a July afternoon. Pre-cool with the doors shut, load at a sealed dock with the unit off, then recovery after the doors close.

Two details matter. First, only pre-cool if the dock is sealed. Opening a cold trailer to humid summer air without a dock seal pulls moisture onto the cold walls and the evaporator coil, and you will pay for it with frost and extra defrost cycles. Second, switch the unit off while the doors are open. A running unit draws warm dock air straight into the return and pushes cold air out of the back of the box.

Check the product, not just the air

The air in a trailer tells you about the trailer. Only a probe in the product tells you about the product. Before a pallet is loaded, someone on the dock should probe a few cases from different pallets and write the readings on the bill of lading. If a pallet is warm, it is far cheaper to hold it at the shipper than to argue about it at the receiver.

Our drivers sign for the temperature now, not just the pallet count. Two refused pickups in the first month, zero rejected deliveries since.
Aoife Brennan, Fleet Manager, Ferngate Foods

Leave room for the air

Cold air leaves the unit at the front, runs along the ceiling, drops at the rear doors and comes back along the floor to the return grille. Anything that blocks that loop creates a warm pocket:

  • Keep pallets clear of the front bulkhead so the return grille can breathe.
  • Respect the load line: a gap of several inches under the ceiling and the air chute.
  • Keep the floor channels clear of debris, slip sheets and loose film.
  • Do not wrap a load in a solid block when the shipper's instructions ask for air between pallets.

The routine, in order

  1. Set the unit to the shipper's set point and the mode they ask for (continuous or start/stop).
  2. Pre-cool with the doors shut until the return air reaches the set point.
  3. Back onto a sealed dock, switch the unit off, open the doors.
  4. Probe the product, record the readings, refuse anything outside the range.
  5. Load to the line, away from the bulkhead, channels clear.
  6. Close, seal, switch the unit on, and note the seal number in the driver app.

What the tracker can and cannot tell you

A Waypoint probe measures the air near where it hangs, every 30 seconds, and the WP‑T4 records every door opening. That is enough to show whether the box was cold before loading, how long the doors were open and how fast it recovered. It is not a product temperature, and we never present it as one. If the receiver probes the product and finds it warm while the box record is clean, the record points you at the shipper's dock, which is exactly the conversation you need to have.

Written by Ines Duarte, qA manager at a pharma wholesaler.

See the box temperature before the receiver does.

Front, middle and rear probes on every reefer, door openings on the map, and a delivery record your receiver can read at the dock.

Pilot on 5 vehicles · Trackers ship in 48 hours

AIR CHUTE1234553 FT · 16.15 MREEFER TRAILER · SIDE ELEVATION