Supply air, return air, product: which temperature are you watching?

A reefer trailer has at least three honest temperatures, and they disagree on purpose. Alerting on the wrong one is how a dispatch room learns to ignore alerts.

Priya RamanHead of Hardware

On this page
  1. 1Supply air: what the unit is making
  2. 2Return air: what the load gives back
  3. 3Product: what the receiver will measure
  4. 4Defrost is a feature
  5. 5So which one should alert?
  6. 6Continuous or start/stop

Every reefer trailer carries several thermometers, and on a healthy unit they never agree. That is not a fault. Each one measures a different part of the system, and each answers a different question. Problems start when an alert rule is attached to the wrong one.

Supply air: what the unit is making

The supply sensor sits where cold air leaves the evaporator and enters the box. It is the coldest reading in the trailer and the one that moves fastest: when the unit cycles, supply air swings by several degrees in minutes. It is the right signal for the health of the refrigeration unit. It is a poor signal for the condition of the load.

Return air: what the load gives back

The return sensor sits at the grille where air comes back to the unit after passing over the cargo. It is warmer than supply, slower to move, and a much better summary of the box. Most controllers regulate on return air for chilled loads for that reason.

Product: what the receiver will measure

The receiver does not care about air. They push a probe between cases or into the product and read a number. Product temperature moves slowly, lagging air by a long way. It is the number that decides whether a load is accepted, and the hardest one to monitor continuously.

DEFROST · 24 MIN0°4°8°12°0 min20 min40 min60 min80 min100 minsupplyreturnproduct
One defrost cycle on a 2–8 °C load. Supply air jumps while the coil is heated; return air barely moves; the product probe does not notice.

Defrost is a feature

As the unit runs, moisture freezes on the evaporator coil and starts to block the airflow. Every few hours, or when the controller detects the coil icing up, the unit stops cooling and heats the coil to melt the ice. While that happens, supply air rises sharply, often well above the set point, for a quarter of an hour or more.

An alert rule on supply air with no delay will page someone every time that happens. After a week of those pages, the dispatch room mutes the channel, and the real failure, when it comes, lands in a muted channel.

Defrost length varies with the unit, the humidity and how often the doors were opened. Look at a month of your own data before you choose a delay: the longest normal defrost on your fleet, plus a margin, is the number. On most chilled trailers we see, it falls between 20 and 40 minutes.

So which one should alert?

  • Alert on return air or a probe in the rear zone, with a delay longer than a typical defrost cycle on that unit. The rear is the warmest part of the box and the first to show a door problem.
  • Use supply air for unit health. A supply temperature that stays high after a defrost ends, or a unit that defrosts every hour, is a maintenance job, not a cold-chain alert.
  • Keep product readings for the record. Probe at loading and at delivery, and attach both to the trip so the receiver sees them next to the air history.

With a wireless probe in the front, middle and rear zones, a WP‑T4 shows a fourth thing the unit's own sensors cannot: the difference between zones. A rear probe that runs three degrees warmer than the front on every trip usually means blocked airflow, not a failing unit.

We had 40 alerts a day and nobody read them. Now we get two or three, and every one is a phone call.
Mei Lin Tan, Maintenance Lead, Quayside Logistics

Continuous or start/stop

Most units can run continuously or cycle on and off to save fuel. Start/stop is fine for frozen loads that hold their temperature well. Fresh produce, flowers and medicines usually ship in continuous mode because constant airflow keeps the zones even. Set the mode from the shipper's instructions and check it is still set when the trailer is picked up, because a mode switched for the previous load is one of the most common causes of an uneven box.

Written by Priya Raman, reefer controller design, 9 years.